Brand Name: | MCreat |
Model Number: | MC-07211 |
MOQ: | 1000 Pieces |
Price: | Negotiable |
Payment Terms: | L/C, T/T |
Supply Ability: | 100, 000PCS/Month |
Closed Suction Catheter (L-Piece) 72hours for Adult, Automatic Flushing 12Fr Endotracheal
Features
Packaging & Delivery
-Packaging Details
-Packing: 1pc/sterilized pouch, 10pcs / inner box, Outer packing: 100pcs / shipping carton
-Delivery Time: Within 20 days. It depends on the quantity of order
Product Description
Clour | Size | Products' Specification & Description | Tube OD | Length of Tube | Product Code |
Black | Adult/72H/Endotracheal | Double Swivel Elbow Endotracheal, Flex Tube | 10Fr (3.35mm) | 600mm | MC-07210 |
White | Adult/72H/Endotracheal | Double Swivel Elbow Endotracheal, Flex Tube | 12Fr (4.05mm) | 600mm | MC-07211 |
Green | Adult/72H/Endotracheal | Double Swivel Elbow Endotracheal, Flex Tube | 14Fr (4.75mm) | 600mm | MC-07212 |
Orange | Adult/72H/Endotracheal | Double Swivel Elbow Endotracheal, Flex Tube | 16Fr (5.45mm) | 600mm | MC-07213 |
Black | Adult/72H/Tracheostomy | Double Swivel Elbow Tracheostomy, Flex Tube | 10Fr (3.35mm) | 300mm | MC-07200 |
White | Adult/72H/Tracheostomy | Double Swivel Elbow Tracheostomy, Flex Tube | 12Fr (4.05mm) | 300mm | MC-07201 |
Green | Adult/72H/Tracheostomy | Double Swivel Elbow Tracheostomy, Flex Tube | 14Fr (4.75mm) | 300mm | MC-07202 |
Orange | Adult/72H/Tracheostomy | Double Swivel Elbow Tracheostomy, Flex Tube | 16Fr (5.45mm) | 300mm | MC-07203 |
We can produce the closed suction catheter according to customers' requirements.
Instructions for Use
*Set up Procedure
1. Inspect the product before use. Do not use it if the package is not intact.
2. Open the sealed package and take out the product.
3. Connect the Endotracheal Tube/Tracheostomy Tube to the Revolvable adapter.
4. Connect ventilator tube to the Revolvable Ventilator Connector.
5. Attach the date label to the color ring.
6. Before suctioning commences ensure that the cap of the MDI Port/ irrigation Port is closed.
7.Before suctioning: Please ensure that the on-off valve is in the open position. Simply slide the on-off valve to a position which allows the catheter to enter the Endotracheal tube/ Tracheostomy tube.
*Suctioning Procedure
Caution-always use the recommended vacuum levels./Consider length of suctioning time
1.Grip the three-way adaptor in one hand and with the other hand feed the suction
a catheter into the Endotracheal tube/ Tracheostomy tube, to the required depth.
Depth markers can be visible through the protective cover for your guidance.
2.Once the suction catheter is in the desired position/ depth depress the vacuum
Control valve to apply suction.
3. Remove the suction catheter until the protective sleeve is straight.
4.Repeat steps1-3 as necessary.