Type Of Sterilization:: | Ethylene Oxide Sterilization | Quality Guarantee Period:: | Five Years |
---|---|---|---|
Logo Printing: | Customized | OEM: | Printed Logo |
Certificate: | CE/ISO13485 | Packaging: | Blister |
High Light: | 10Fr Closed Circuit Suction Catheter,Double Swivel Elbows Closed Circuit Suction Catheter,10Fr closed suction tube |
Closed Suction System Double Swivel Elbows (Y-Piece) 24H Endotracheal 10Fr
Features
- Continuous Breathing
Simultaneously ventilation
- Soft Blue Suction Tip
This design reduces damage to the patient while suctioning.
After returning the catheter, the tip of the tube is easier for irrigational cleaning.
- Double Swivel Connector
15mm connector of Double Swivel
- Disconnecting Wedge
Designed to equip the wedge with both disconnecting and clipping functions
- For Endotracheal Tube and Tracheostomy Tube
Designed for endotracheal and tracheostomy tube using
Tubes with different length are available
- Prevent Cross Infection
Designed with a protective sleeve to isolate the bacteria inside and help caregivers avoid cross-inflection.
Packaging & Delivery
-Packaging Details
-Packing: 1pc/sterilized pouch, 10pcs / inner box, Outer packing: 100pcs / shipping carton
-Delivery Time: Within 20 days. It depends on the quantity of order
Product Description
Clour | Size | Products' Specification & Description | Tube OD | Length of Tube |
Ivory | 24H/Endotracheal | Double Swivel Elbow Tracheostomy, Built in MDI Adapter, Flex Tube | 7Fr | 300mm |
Light Blue | 24H/Endotracheal | Double Swivel Elbow Tracheostomy, Built in MDI Adapter, Flex Tube | 8Fr | 300mm |
Black | 24H/Endotracheal | Double Swivel Elbow Endotracheal, Built in MDI Adapter, Flex Tube | 10Fr | 600mm |
White | 24H/Endotracheal | Double Swivel Elbow Endotracheal, Built in MDI Adapter, Flex Tube | 12Fr | 600mm |
Green | 24H/Endotracheal | Double Swivel Elbow Endotracheal, Built in MDI Adapter, Flex Tube | 14Fr | 600mm |
Orange | 24H/Endotracheal | Double Swivel Elbow Endotracheal, Built in MDI Adapter, Flex Tube | 16Fr | 600mm |
We can produce the closed suction catheter according to customers' requirements.
Instructions for Use
*Set up Procedure
1. Inspect the product before use. Do not use it if the package is not intact.
2. Open the sealed package and take out the product.
3. Connect the Endotracheal Tube/Tracheostomy Tube to the Revolvable adapter.
4. Connect ventilator tube to the Revolvable Ventilator Connector.
5. Attach the date label to the color ring.
6. Before suctioning commences ensure that the cap of the MDI Port/ irrigation Port is closed.
7.Before suctioning: Please ensure that the on-off valve is in the open position. Simply slide the on-off valve to a position which allows the catheter to enter the Endotracheal tube/ Tracheostomy tube.
*Suctioning Procedure
Caution-always use the recommended vacuum levels./Consider length of suctioning time
1.Grip the three-way adaptor in one hand and with the other hand feed the suction
a catheter into the Endotracheal tube/ Tracheostomy tube, to the required depth.
Depth markers can be visible through the protective cover for your guidance.
2.Once the suction catheter is in the desired position/ depth depress the vacuum
Control valve to apply suction.
3. Remove the suction catheter until the protective sleeve is straight.
4.Repeat steps1-3 as necessary.
Company Profile
Founded in 2015, MCREAT (GUANGZHOU) BIO-TECH CO., LTD. is located in Huachuang Animation Industrial Park, the "first City of Cultural and Creative Industries in China" gathered by thousands of enterprises in Panyu District, Guangzhou City. There is a plant area of 5,300 square meters, a production workshop of 2,500 square meters, including 2,200 square meters of 100,000 level purification workshop, a warehouse of 900 square meters, and a biological experiment center of 300 square meters. There are more than 30 sets of main production equipment and 6 sets of inspection equipment. With 195 staff, including 31 managers, 13 production technicians and 151 operators, the company’ s personnel management, product quality management system, production, testing equipment, technical capacity, etc. can meet the product requirements.