Brand Name: | MCREAT/OEM |
Model Number: | MC-02400 |
MOQ: | 1000 |
Price: | USD 2.7-3.5/PC |
Payment Terms: | L/C, Western Union, , T/T |
Supply Ability: | 480, 000PCS/Year |
Medical All Sizes Closed Suction Catheter With Soft Blue Suction Tip
Closed Suction Catheter can be helpful in limiting environmental, personnel and patient contamination and in preventing the loss of lung volume and the alveolar derecruitment associated with standard suctioning in the severely hypoxemic patients.
Product Parameter
Product Code | Size | Colour Code | Tube OD (mm) | Length of Tube (mm) |
MC-02400 | Neonatal/24H/Tracheostomy | Grey | 5Fr(1.7mm) | 300mm |
MC-02401 | Neonatal//24H/Tracheostomy | Light Green | 6Fr(1.95mm) | 300mm |
MC-02402 | Pediatric/24H/Tracheostomy | Lvory | 7Fr(2.3mm) | 300mm |
MC-02403 | Pediatric//24H/Tracheostomy | Light Blue | 8Fr(2.7mm) | 300mm |
MC-02404 | Adult/24H/Tracheostomy | Black | 10Fr(3.35mm) | 300mm |
MC-02405 | Adult/24H/Tracheostomy | White | 12Fr(4.05mm) | 300mm |
MC-02406 | Adult/24H/Tracheostomy | Green | 14Fr(4.75mm) | 300mm |
MC-02407 | Adult/24H/Tracheostomy | Orange | 16Fr(5.45mm) | 300mm |
Product Code | Size | Colour Code | Tube OD (mm) | Length of Tube (mm) |
MC-02410 | Neonatal/24H/Endotracheal | Grey | 5Fr(1.7mm) | 300mm |
MC-02411 | Neonatal//24H/Endotracheal | Light Green | 6Fr(1.95mm) | 300mm |
MC-02412 | Pediatric/24H/Endotracheal | Lvory | 7Fr(2.3mm) | 300mm |
MC-02413 | Pediatric//24H/Endotracheal | Light Blue | 8Fr(2.7mm) | 300mm |
MC-02414 | Adult/24H/Endotracheal | Black | 10Fr(3.35mm) | 600mm |
MC-02415 | Adult/24H/Endotracheal | White | 12Fr(4.05mm) | 600mm |
MC-02416 | Adult/24H/Endotracheal | Green | 14Fr(4.75mm) | 600mm |
MC-02417 | Adult/24H/Endotracheal | Orange | 16Fr(5.45mm) | 600mm |
Instructions For Use
1. Unlock the thumb control valve
2. Stabilize the catheter and endotracheal tube by firmly holding the T-Piece or Elbow with one hand and inserting the catheter into the endotracheal tube or tracheostomy tube by advancing the catheter between the thumb and forefinger of the opposite hand to the desired depth.
3. Activate suction by depressing the thumb control valve while gently withdrawing the catheter. Stop when the black band on the catheter is visible in the sheath.
4. Release the thumb control valve.
5. For subsequent suctioning repeat step 1 to 4
6. After the suction procedure rinse the catheter by attaching a saline vial or syringe to the rinse port and gently instill saline or established fluid while depressing the thumb control valve simultaneously.