Type Of Sterilization:: | Ethylene Oxide Sterilization | Quality Guarantee Period:: | Five Years |
---|---|---|---|
Material: | Medical Grade PVC | OEM: | Printed Logo |
Instrument Classification: | Class II | Size: | 14Fr |
High Light: | 14Fr closed suction catheter,PVC Medical closed suction catheter,Ethylene Oxide Sterilization closed suction catheter |
Closed Suction Catheter (L-Piece) 72hours for Adult, Automatic Flushing 14Fr Tracheostomy
Features
- Continuous Breathing
Simultaneously ventilation
- Soft Blue Suction Tip
This design reduces damage to the patient while suctioning.
After returning the catheter, the tip of the tube is easier for irrigational cleaning.
- Double Swivel Connector
15mm connector of Double Swivel
- Disconnecting Wedge
Designed to equip the wedge with both disconnecting and clipping functions
- For Endotracheal Tube and Tracheostomy Tube
Designed for endotracheal and tracheostomy tube using
Tubes with different length are available
- Prevent Cross Infection
Designed with a protective sleeve to isolate the bacteria inside and help caregivers avoid cross-inflection.
Packaging & Delivery
-Packaging Details
-Packing: 1pc/sterilized pouch, 10pcs / inner box, Outer packing: 100pcs / shipping carton
-Delivery Time: Within 20 days. It depends on the quantity of order
Product Description
Clour | Size | Products' Specification & Description | Tube OD | Length of Tube | Product Code |
Black | Adult/72H/Endotracheal | Double Swivel Elbow Endotracheal, Flex Tube | 10Fr (3.35mm) | 600mm | MC-07210 |
White | Adult/72H/Endotracheal | Double Swivel Elbow Endotracheal, Flex Tube | 12Fr (4.05mm) | 600mm | MC-07211 |
Green | Adult/72H/Endotracheal | Double Swivel Elbow Endotracheal, Flex Tube | 14Fr (4.75mm) | 600mm | MC-07212 |
Orange | Adult/72H/Endotracheal | Double Swivel Elbow Endotracheal, Flex Tube | 16Fr (5.45mm) | 600mm | MC-07213 |
Black | Adult/72H/Tracheostomy | Double Swivel Elbow Tracheostomy, Flex Tube | 10Fr (3.35mm) | 300mm | MC-07200 |
White | Adult/72H/Tracheostomy | Double Swivel Elbow Tracheostomy, Flex Tube | 12Fr (4.05mm) | 300mm | MC-07201 |
Green | Adult/72H/Tracheostomy | Double Swivel Elbow Tracheostomy, Flex Tube | 14Fr (4.75mm) | 300mm | MC-07202 |
Orange | Adult/72H/Tracheostomy | Double Swivel Elbow Tracheostomy, Flex Tube | 16Fr (5.45mm) | 300mm | MC-07203 |
We can produce the closed suction catheter according to customers' requirements.
Instructions for Use
*Set up Procedure
1. Inspect the product before use. Do not use it if the package is not intact.
2. Open the sealed package and take out the product.
3. Connect the Endotracheal Tube/Tracheostomy Tube to the Revolvable adapter.
4. Connect ventilator tube to the Revolvable Ventilator Connector.
5. Attach the date label to the color ring.
6. Before suctioning commences ensure that the cap of the MDI Port/ irrigation Port is closed.
7.Before suctioning: Please ensure that the on-off valve is in the open position. Simply slide the on-off valve to a position which allows the catheter to enter the Endotracheal tube/ Tracheostomy tube.
*Suctioning Procedure
Caution-always use the recommended vacuum levels./Consider length of suctioning time
1.Grip the three-way adaptor in one hand and with the other hand feed the suction
a catheter into the Endotracheal tube/ Tracheostomy tube, to the required depth.
Depth markers can be visible through the protective cover for your guidance.
2.Once the suction catheter is in the desired position/ depth depress the vacuum
Control valve to apply suction.
3. Remove the suction catheter until the protective sleeve is straight.
4.Repeat steps1-3 as necessary.
Company Profile
The company's business philosophy is "ingenuity quality, intelligent medical care" as its purpose, guiding the efforts of all colleagues in the concept and growing up under the love of all walks of life, laying a solid foundation for development. Since the establishment of the company, we have adhered to the highest guiding principles of honesty and trustworthiness, initiative, steadfastness, and sustainable operation. We hope that every employee can be responsible for life, the company, and the society with a positive and enterprising attitude. At the same time, we also hope that the company will safely produce and sell effective and reasonably priced medical devices under the down-to-earth struggle of all colleagues.